{"id":37069,"date":"2025-08-04T13:21:46","date_gmt":"2025-08-04T13:21:46","guid":{"rendered":"https:\/\/calibration.consulting\/product\/clarke-hess-610-and-650-current-shunts\/"},"modified":"2025-08-04T13:21:46","modified_gmt":"2025-08-04T13:21:46","slug":"clarke-hess-610-and-650-current-shunts","status":"publish","type":"product","link":"https:\/\/calibration.consulting\/en\/product\/clarke-hess-610-and-650-current-shunts\/","title":{"rendered":"Clarke-Hess 610 and 650 current shunts"},"content":{"rendered":"<p>The <a href=\"https:\/\/calibration.consulting\/en\/supplier\/clarke-hess\/\" target=\"_blank\" rel=\"noopener\">Clarke-Hess<\/a> 610 and 650 current shunts are specifically designed to work with the <a href=\"https:\/\/calibration.consulting\/en\/product\/clarke-hess-6000a-phase-meter\/\" target=\"_blank\" rel=\"noopener\">Clarke-Hess 6000A<\/a> Precision Phase Meter and Power analysers. These current shunts are frequency-optimised and offer a negligible phase shift of less than \u00b15 m\u00ba at 50\/60 Hz. Thanks to their wide frequency range and high accuracy, the 610 and 650 shunts are suitable for power tests, phase angle measurements and calibration of power meters and analysers.<\/p>\n<h3>High accuracy and minimal phase shift<\/h3>\n<p>The Clarke-Hess 610 and 650 shunts are frequency-tuned, providing exceptionally stable performance:<\/p>\n<ul>\n<li><strong>&gt; Model 610<\/strong>: Current range 1A \u2013 10A, frequency range 5 Hz \u2013 100 kHz\n<ul>\n<li>* &lt;5 m\u00ba phase shift up to 1 kHz<\/li>\n<li>* 5m\u00ba + 50m\u00ba (f-1) above 1 kHz<\/li>\n<\/ul>\n<\/li>\n<li><strong>&gt; Model 650<\/strong>: Current range 10A \u2013 50A, frequency range 5 Hz \u2013 1 kHz\n<ul>\n<li>* &lt;5 m\u00ba phase shift up to 100 Hz<\/li>\n<li>* &lt;10 m\u00ba phase shift up to 500 Hz<\/li>\n<li>* 50 m\u00ba phase shift above 500 Hz<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<h3>Optimised for laboratory and industrial applications<\/h3>\n<p>The 610 and 650 models provide high-precision current measurement without significant phase errors, which is crucial for:<\/p>\n<p>&gt; Power measurements in power frequency and high frequency applications<br \/>\n&gt; Calibration of current transformers and precision ammeters<br \/>\n&gt; Research and development in power electronics and power quality testing<br \/>\n&gt; Compatibility with the Clarke-Hess 6000A for accurate phase angle measurements<\/p>\n<h3>Technical specifications<\/h3>\n<ul>\n<li><strong>&gt; Model 610<\/strong>: 1A \u2013 10A, 5 Hz \u2013 100 kHz<\/li>\n<li><strong>&gt; Model 650<\/strong>: 10A \u2013 50A, 5 Hz \u2013 1 kHz<\/li>\n<li><strong>&gt; Phase shift<\/strong>:\n<ul>\n<li>* &lt;5 m\u00ba to 1 kHz (Model 610)<\/li>\n<li>* &lt;10 m\u00ba to 500 Hz (Model 650)<\/li>\n<li>* 50 m\u00ba above 500 Hz (Model 650)<\/li>\n<\/ul>\n<\/li>\n<li>&gt; Ideal for use with the Clarke Hess 6000A Phase Meter<\/li>\n<li>&gt; Tuned frequency response for minimal phase errors<\/li>\n<\/ul>\n<p>The Clarke-Hess 610 and 650 Current Shunts offer exceptional precision and stability, making them essential for current and phase angle measurements in both laboratory and industrial applications.<\/p>\n","protected":false},"excerpt":{"rendered":"<ul>\n<li>Model 610: 1A &#8211; 10A, 5 Hz &#8211; 100 kHz<\/li>\n<li>Model 650: 10A &#8211; 50A, 5 Hz &#8211; 1 kHz<\/li>\n<li>Phase shift:\n<ul>\n<li>&lt;5 m\u00ba to 1 kHz (Model 610)<\/li>\n<li>&lt;10 m\u00ba to 500 Hz (Model 650)<\/li>\n<li>50 m\u00ba above 500 Hz (Model 650)<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n","protected":false},"featured_media":37065,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"_seopress_robots_primary_cat":"none","_seopress_titles_title":"Clarke-Hess 610 and 650 current shunts","_seopress_titles_desc":"The Clarke-Hess 610 and 650 current shunts are specially designed to work with the Clarke-Hess 6000A Precision Phase Meter and Power analysers.","_seopress_robots_index":""},"product_brand":[],"product_cat":[249,250,259],"product_tag":[],"class_list":["post-37069","product","type-product","status-publish","has-post-thumbnail","product_cat-calibration-en","product_cat-electrical-calibration","product_cat-current-measurements","first","instock","shipping-taxable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/calibration.consulting\/en\/wp-json\/wp\/v2\/product\/37069","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/calibration.consulting\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/calibration.consulting\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/calibration.consulting\/en\/wp-json\/wp\/v2\/comments?post=37069"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/calibration.consulting\/en\/wp-json\/wp\/v2\/media\/37065"}],"wp:attachment":[{"href":"https:\/\/calibration.consulting\/en\/wp-json\/wp\/v2\/media?parent=37069"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/calibration.consulting\/en\/wp-json\/wp\/v2\/product_brand?post=37069"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/calibration.consulting\/en\/wp-json\/wp\/v2\/product_cat?post=37069"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/calibration.consulting\/en\/wp-json\/wp\/v2\/product_tag?post=37069"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}