{"id":1975,"date":"2023-08-01T14:28:26","date_gmt":"2023-08-01T14:28:26","guid":{"rendered":"https:\/\/calibration.consulting\/product\/mi-9331g-high-accuracy-resistance-standards\/"},"modified":"2023-09-13T10:53:17","modified_gmt":"2023-09-13T10:53:17","slug":"mi-9331r-reference-precision-standard-air-resistors-2","status":"publish","type":"product","link":"https:\/\/calibration.consulting\/en\/product\/mi-9331r-reference-precision-standard-air-resistors-2\/","title":{"rendered":"MI 9331G High Accuracy Resistance Standards"},"content":{"rendered":"<h3>MI 9331G High Accuracy Resistance Standards<\/h3>\n<p>The <a href=\"https:\/\/tt-ms.com\/supplier\/measurements-international\/\" target=\"_blank\" rel=\"noopener noreferrer\">MI<\/a> 9331G series of High Accuracy Resistance Standards are available in standard values from 10 M\u03a9 to 100 T\u03a9 and custom values available at any resistance therein.<\/p>\n<p>High stability and supplied alpha and beta temperature coefficients of the 9331G make them ideal for easy transport and operation in any working environment within the range of 18 \u00b0C to 28 \u00b0C. The resistance standards require no controlled oil or air bath to meet specifications, however, for improved performance, they can be placed in an air bath such as the model 9300 or 9300A.<\/p>\n<p>The Measurement International 9331G is based on a NIST design which includes the split guard design and internal temperature sensor. The split guard circuit design allows for applying independent guard voltages at each side of the resistor.<\/p>\n<p>All resistor connections are type N. There are\u00a0 Several adapter cables from N-Type to GR and BNC available.<\/p>\n<p>The Measurements International 9331G series of High Accuracy Resistance Standards are hermetically sealed in a shielded enclosure and isolated from the case.<\/p>\n<p>For more information about <a href=\"https:\/\/tt-ms.com\/products\/calibration-en\/electrical-calibration\/elektrische-standaarden\/\" target=\"_blank\" rel=\"noopener noreferrer\">electrical standards<\/a> and <a href=\"https:\/\/tt-ms.com\/products\/calibration-en\/electrical-calibration\/resistance\/\" target=\"_blank\" rel=\"noopener noreferrer\">resistors<\/a>, please refer to the overview pages or contact one of our consultants<\/p>\n<p>They will be happy to help you find the right solution for your application.<\/p>\n","protected":false},"excerpt":{"rendered":"<ul>\n<li>High Stability<\/li>\n<li>10M to 100T Ohms<\/li>\n<li>Split Guard Circuit<\/li>\n<li>Internal Temperature Sensor<\/li>\n<li>Custom Values Available<\/li>\n<li>NIST Design<\/li>\n<li>Includes Calibration Data<\/li>\n<\/ul>\n","protected":false},"featured_media":1556,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"_seopress_titles_title":"","_seopress_titles_desc":"MI 9331R Reference Series of Precision Standard Air Resistors.This 9331R series of Air Resistors was developed to close the gap between high accuracy and","_seopress_robots_index":"","_seopress_robots_follow":"","_seopress_robots_imageindex":"","_seopress_robots_snippet":"","_seopress_robots_primary_cat":"none","_seopress_robots_breadcrumbs":"","_seopress_robots_freeze_modified_date":"","_seopress_robots_custom_modified_date":"","_seopress_robots_canonical":"","_seopress_social_fb_title":"","_seopress_social_fb_desc":"","_seopress_social_fb_img":"","_seopress_social_fb_img_attachment_id":0,"_seopress_social_fb_img_width":0,"_seopress_social_fb_img_height":0,"_seopress_social_twitter_title":"","_seopress_social_twitter_desc":"","_seopress_social_twitter_img":"","_seopress_social_twitter_img_attachment_id":0,"_seopress_social_twitter_img_width":0,"_seopress_social_twitter_img_height":0,"_seopress_redirections_value":"","_seopress_redirections_enabled":"","_seopress_redirections_enabled_regex":"","_seopress_redirections_logged_status":"both","_seopress_redirections_param":"","_seopress_redirections_type":301,"_seopress_analysis_target_kw":"MI 9331R Reference Precision Standard Air Resistors","_seopress_news_disabled":"","_seopress_video_disabled":"","_seopress_video":[],"_seopress_pro_schemas_manual":[],"_seopress_pro_rich_snippets_disable_all":"","_seopress_pro_rich_snippets_disable":[],"_seopress_pro_schemas":[]},"product_brand":[],"product_cat":[253],"product_tag":[],"class_list":["post-1975","product","type-product","status-publish","has-post-thumbnail","product_cat-electrical-standards","first","instock","shipping-taxable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/calibration.consulting\/en\/wp-json\/wp\/v2\/product\/1975","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/calibration.consulting\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/calibration.consulting\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/calibration.consulting\/en\/wp-json\/wp\/v2\/comments?post=1975"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/calibration.consulting\/en\/wp-json\/wp\/v2\/media\/1556"}],"wp:attachment":[{"href":"https:\/\/calibration.consulting\/en\/wp-json\/wp\/v2\/media?parent=1975"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/calibration.consulting\/en\/wp-json\/wp\/v2\/product_brand?post=1975"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/calibration.consulting\/en\/wp-json\/wp\/v2\/product_cat?post=1975"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/calibration.consulting\/en\/wp-json\/wp\/v2\/product_tag?post=1975"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}