{"id":1904,"date":"2023-08-01T14:26:22","date_gmt":"2023-08-01T14:26:22","guid":{"rendered":"https:\/\/calibration.consulting\/product\/isotech-primary-sprt-670-family-thermometers\/"},"modified":"2025-04-10T08:22:35","modified_gmt":"2025-04-10T08:22:35","slug":"isotech-primary-sprt-670-family-thermometers","status":"publish","type":"product","link":"https:\/\/calibration.consulting\/en\/product\/isotech-primary-sprt-670-family-thermometers\/","title":{"rendered":"Isotech Primary SPRT 670 Family Thermometers"},"content":{"rendered":"<p>The <a href=\"https:\/\/tt-ms.com\/supplier\/isotech-2\/\" target=\"_blank\" rel=\"noopener\">Isotech<\/a> 670 series consists of ultra-stable standard platinum resistance thermometers (SPRTs) designed for primary and secondary laboratories. With a temperature range of -200\u00b0C to 670\u00b0C and unmatched performance in terms of stability, reproducibility and low drift, these thermometers are ideal for high-performance temperature calibrations according to the ITS-90.<\/p>\n<p>The 670SQ, 670SH and 670SL are specially designed to provide optimum performance in various laboratory environments. The 670SQ, built with all-quartz glass construction, offers the best performance for achieving minimum drift and maximum reproducibility, while the metal versions (670SH and 670SL) offer high mechanical strength and durability.<\/p>\n<h3>Outstanding Stability and Construction<\/h3>\n<p>The 670SQ is designed with an innovative internal structure that minimizes thermal expansion and contraction. The four internal platinum conductors can move independently, eliminating mechanical stresses. In addition, a platinum heat shield prevents radiation losses, leading to exceptional stability.<\/p>\n<p>The construction of the 670SH and 670SL includes a metal jacket, providing additional robustness for environments where mechanical impact or vibration may occur. The low-temperature 670SL variant is specially optimized for applications down to -200\u00b0C, while the 670SH is suitable for use up to the aluminum fixed point of 660.323\u00b0C.<\/p>\n<h3>Technical Specifications<\/h3>\n<table>\n<thead>\n<tr>\n<td><strong>Model<\/strong><\/td>\n<td><strong>Range(\u00b0C)<\/strong><\/td>\n<td><strong>Ro (\u03a9)<\/strong><\/td>\n<td><strong>Sheat Material<\/strong><\/td>\n<td><strong>Diameter<\/strong><\/td>\n<td><strong>Length<\/strong><\/td>\n<td><strong>Measurement Area<\/strong><\/td>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><strong>670SQ<\/strong><\/td>\n<td>-200 to 670<\/td>\n<td>25.5<\/td>\n<td>Quartz<\/td>\n<td>7,5 mm<\/td>\n<td>650 mm<\/td>\n<td>35 mm<\/td>\n<\/tr>\n<tr>\n<td><strong>670SH<\/strong><\/td>\n<td>-80 to 670<\/td>\n<td>25.5<\/td>\n<td>Metal<\/td>\n<td>6 mm<\/td>\n<td>650 mm<\/td>\n<td>35 mm<\/td>\n<\/tr>\n<tr>\n<td><strong>670SL<\/strong><\/td>\n<td>-200 to 165<\/td>\n<td>25.5<\/td>\n<td>Metal<\/td>\n<td>6 mm<\/td>\n<td>480 mm<\/td>\n<td>35 mm<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>The 670SQ is recommended for primary laboratories because of its low self-heating. The metal housing makes the 670SH suitable for more robust high-temperature applications, while the 670SL offers a cost-effective solution for low-temperature applications.<\/p>\n<h3>UKAS Calibration and Accuracy<\/h3>\n<p>For optimum accuracy, the 670 series can be supplied with UKAS calibration, including validation at ITS-90 fixed points.<\/p>\n<table>\n<thead>\n<tr>\n<td><strong>Fixed Point<\/strong><\/td>\n<td><strong>Temperature (\u00b0C)<\/strong><\/td>\n<td><strong>UKAS Uncertainly (k=2)<\/strong><\/td>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><strong>Argon Triple Point<\/strong><\/td>\n<td>-189,3442<\/td>\n<td>0,5 mK<\/td>\n<\/tr>\n<tr>\n<td><strong>Mercury Triple Point<\/strong><\/td>\n<td>-38,8344<\/td>\n<td>0,3 mK<\/td>\n<\/tr>\n<tr>\n<td><strong>Water Triple Point<\/strong><\/td>\n<td>0,01<\/td>\n<td>0,1 mK<\/td>\n<\/tr>\n<tr>\n<td><strong>Gallium Melting point<\/strong><\/td>\n<td>29,7646<\/td>\n<td>0,2 mK<\/td>\n<\/tr>\n<tr>\n<td><strong>Indium fixed point<\/strong><\/td>\n<td>156,5985<\/td>\n<td>1 mK<\/td>\n<\/tr>\n<tr>\n<td><strong>Tin fixed point<\/strong><\/td>\n<td>231,928<\/td>\n<td>1 mK<\/td>\n<\/tr>\n<tr>\n<td><strong>Zinc fixed point<\/strong><\/td>\n<td>419,527<\/td>\n<td>1,2 mK<\/td>\n<\/tr>\n<tr>\n<td><strong>Aluminium fixed point<\/strong><\/td>\n<td>660,323<\/td>\n<td>2 mK<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>The 670SQ is delivered after an extensive stabilization process, which verifies the reproducibility of RTPW within 0.0005\u00b0C after exposure to the extreme temperatures within the operating range.<\/p>\n<h3>Applications<\/h3>\n<p>The Isotech 670 series is ideal for:<\/p>\n<p>Primary and secondary laboratories working with ITS-90 standards.<br \/>\nTemperature calibration of SPRTs and industrial PRTs.<br \/>\nInterlaboratory comparisons and accreditation audits.<br \/>\nResearch and development of advanced temperature standards.<\/p>\n<p>Each thermometer comes in a soft-lined carrying case, along with a comprehensive manual for optimal performance and longevity.<\/p>\n","protected":false},"excerpt":{"rendered":"<ul>\n<li>Useable Range -200\u00b0C to 670 \u00b0C<\/li>\n<li>25.5 Ohm SPRT<\/li>\n<li>Outstanding Performance<\/li>\n<li>Long term drift from 0.001\u00b0C \/ year dependingon use<\/li>\n<li>Sensitivity 0.1\u03a9 \/ \u00b0C (25.5\u03a9) ,0.4\u03a9 \/ \u00b0C (100\u03a9)<\/li>\n<\/ul>\n","protected":false},"featured_media":33441,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"_seopress_titles_title":"","_seopress_titles_desc":"Isotech Primary SPRT 670 Family Thermometers can now offer 25.5 Ohm (Ro) and 100 Ohm (Ro). The construction, including the spiral sensor element, heat","_seopress_robots_index":"","_seopress_robots_follow":"","_seopress_robots_imageindex":"","_seopress_robots_snippet":"","_seopress_robots_primary_cat":"none","_seopress_robots_breadcrumbs":"","_seopress_robots_freeze_modified_date":"","_seopress_robots_custom_modified_date":"","_seopress_robots_canonical":"","_seopress_social_fb_title":"","_seopress_social_fb_desc":"","_seopress_social_fb_img":"","_seopress_social_fb_img_attachment_id":0,"_seopress_social_fb_img_width":0,"_seopress_social_fb_img_height":0,"_seopress_social_twitter_title":"","_seopress_social_twitter_desc":"","_seopress_social_twitter_img":"","_seopress_social_twitter_img_attachment_id":0,"_seopress_social_twitter_img_width":0,"_seopress_social_twitter_img_height":0,"_seopress_redirections_value":"","_seopress_redirections_enabled":"","_seopress_redirections_enabled_regex":"","_seopress_redirections_logged_status":"both","_seopress_redirections_param":"","_seopress_redirections_type":301,"_seopress_analysis_target_kw":"Isotech Primary SPRT 670,Thermometer","_seopress_news_disabled":"","_seopress_video_disabled":"","_seopress_video":[],"_seopress_pro_schemas_manual":[],"_seopress_pro_rich_snippets_disable_all":"","_seopress_pro_rich_snippets_disable":[],"_seopress_pro_schemas":[]},"product_brand":[],"product_cat":[263,270,249],"product_tag":[],"class_list":["post-1904","product","type-product","status-publish","has-post-thumbnail","product_cat-temperature-calibration","product_cat-temperatuur-sensoren","product_cat-calibration-en","first","instock","shipping-taxable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/calibration.consulting\/en\/wp-json\/wp\/v2\/product\/1904","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/calibration.consulting\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/calibration.consulting\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/calibration.consulting\/en\/wp-json\/wp\/v2\/comments?post=1904"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/calibration.consulting\/en\/wp-json\/wp\/v2\/media\/33441"}],"wp:attachment":[{"href":"https:\/\/calibration.consulting\/en\/wp-json\/wp\/v2\/media?parent=1904"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/calibration.consulting\/en\/wp-json\/wp\/v2\/product_brand?post=1904"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/calibration.consulting\/en\/wp-json\/wp\/v2\/product_cat?post=1904"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/calibration.consulting\/en\/wp-json\/wp\/v2\/product_tag?post=1904"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}