{"id":1859,"date":"2023-08-01T14:26:21","date_gmt":"2023-08-01T14:26:21","guid":{"rendered":"https:\/\/calibration.consulting\/product\/iet-high-power-resistance-decadence-substitute-hprs\/"},"modified":"2023-09-12T09:24:20","modified_gmt":"2023-09-12T09:24:20","slug":"iet-high-power-resistance-decadence-substitute-hprs","status":"publish","type":"product","link":"https:\/\/calibration.consulting\/en\/product\/iet-high-power-resistance-decadence-substitute-hprs\/","title":{"rendered":"IET High Power Resistance Decadence Substitute (HPRS)"},"content":{"rendered":"<h3>IET HIGH POWER RESISTANCE DECADENT SUBSTITUTE<\/h3>\n<p>The <a href=\"https:\/\/tt-ms.com\/supplier\/iet\/\" target=\"_blank\" rel=\"noopener noreferrer\">IET<\/a> High Power Resistance Decadence Substitute (HPRS) series is a family of resistance decade banks with a wide choice of high power resistor sources with excellent performance.<\/p>\n<p>The HPRS series uses state-of-the-art precision resistors of different types for high accuracy, high stability and low temperature and power coefficients. High-power resistors within the unit are available without sacrificing other electrical properties.<\/p>\n<p>The standard models offer a choice of 3-8 decades. The panels have labels that clearly indicate the step size, maximum voltage and current limits for each decade.<\/p>\n<p>With a resolution starting at 1 m\u03a9 and a maximum resistance of 10 M\u03a9, the HPRS resistance decoder can be used as a general substitute, but also as a high power load for power supply testing and other high power applications.<\/p>\n<p>Applications include meter and instrument calibration. HPRS resistor decades are useful development tools where accurate resistors with high power properties are required for processing.<\/p>\n<h3>MODELS<\/h3>\n<table style=\"height: 534px;\" width=\"680\">\n<tbody>\n<tr>\n<td rowspan=\"2\" width=\"111\"><strong>Resistance per step<\/strong><\/td>\n<td rowspan=\"2\" width=\"75\"><strong>Total decade resistance<\/strong><\/td>\n<td rowspan=\"2\" width=\"73\"><strong>Max current*<\/strong><\/td>\n<td width=\"112\"><strong>Max power per step*\u00a0<\/strong><\/td>\n<td width=\"133\"><strong>Temperature coefficient\u00a0<\/strong><\/td>\n<td width=\"80\"><strong>Resistor Type<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"112\"><strong>(W)<\/strong><\/td>\n<td width=\"133\"><strong>(ppm\/\u00b0C)<\/strong><\/td>\n<td width=\"80\"><\/td>\n<\/tr>\n<tr>\n<td width=\"111\">1 m\u03a9<\/td>\n<td width=\"75\">0.009 \u03a9<\/td>\n<td width=\"73\">8:00 AM<\/td>\n<td width=\"112\">0.036<\/td>\n<td width=\"133\">\u00b150<\/td>\n<td width=\"80\">Resistance Wire<\/td>\n<\/tr>\n<tr>\n<td width=\"111\">10 m\u03a9<\/td>\n<td width=\"75\">0.09 \u03a9<\/td>\n<td width=\"73\">6:00 AM<\/td>\n<td width=\"112\">0.36<\/td>\n<td width=\"133\">\u00b150<\/td>\n<td width=\"80\">Resistance Wire<\/td>\n<\/tr>\n<tr>\n<td width=\"111\">100 m\u03a9<\/td>\n<td width=\"75\">0.9 \u03a9<\/td>\n<td width=\"73\">6:00 AM<\/td>\n<td width=\"112\">3.6<\/td>\n<td width=\"133\">\u00b120<\/td>\n<td width=\"80\">Resistance Wire<\/td>\n<\/tr>\n<tr>\n<td width=\"111\">1 \u03a9<\/td>\n<td width=\"75\">9 \u03a9<\/td>\n<td width=\"73\">5:00 AM<\/td>\n<td width=\"112\">25<\/td>\n<td width=\"133\">-20 to +80<\/td>\n<td width=\"80\">Power Film<\/td>\n<\/tr>\n<tr>\n<td width=\"111\">10 \u03a9<\/td>\n<td width=\"75\">90 \u03a9<\/td>\n<td width=\"73\">1.5 A<\/td>\n<td width=\"112\">25<\/td>\n<td width=\"133\">-20 to +80<\/td>\n<td width=\"80\">Power Film<\/td>\n<\/tr>\n<tr>\n<td width=\"111\">100 \u03a9<\/td>\n<td width=\"75\">900 \u03a9<\/td>\n<td width=\"73\">0.5 A<\/td>\n<td width=\"112\">25<\/td>\n<td width=\"133\">-20 to +80<\/td>\n<td width=\"80\">Power Film<\/td>\n<\/tr>\n<tr>\n<td width=\"111\">1 k\u03a9<\/td>\n<td width=\"75\">9 k\u03a9<\/td>\n<td width=\"73\">150 mA\u2020<\/td>\n<td width=\"112\">25\u2020<\/td>\n<td width=\"133\">-20 to +80<\/td>\n<td width=\"80\">Power Film<\/td>\n<\/tr>\n<tr>\n<td width=\"111\">10 k\u03a9<\/td>\n<td width=\"75\">90 k\u03a9<\/td>\n<td width=\"73\">50 mA\u2020<\/td>\n<td width=\"112\">25\u2020<\/td>\n<td width=\"133\">-20 to +80<\/td>\n<td width=\"80\">Power Film<\/td>\n<\/tr>\n<tr>\n<td width=\"111\">100 k\u03a9<\/td>\n<td width=\"75\">900 k\u03a9<\/td>\n<td width=\"73\">V limit\u2020<\/td>\n<td width=\"112\">V limit\u2020<\/td>\n<td width=\"133\">-20 to +80<\/td>\n<td width=\"80\">Wirewound\/ metal film<\/td>\n<\/tr>\n<tr>\n<td width=\"111\">1 M\u03a9<\/td>\n<td width=\"75\">9 M\u03a9<\/td>\n<td width=\"73\">V limit\u2020<\/td>\n<td width=\"112\">V limit\u2020<\/td>\n<td width=\"133\">\u00b150<\/td>\n<td width=\"80\">Wirewound\/film<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<ul>\n<li>Resistance from 1 m\u03a9 to 10 M\u03a9<\/li>\n<li>Wide choice: 3 to 9 decade units<\/li>\n<li>Accuracy: 0.5% or 1%<\/li>\n<li>Power Rating : 225 W\/decade, 250 W max. or higher<\/li>\n<\/ul>\n","protected":false},"featured_media":1404,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"_seopress_robots_primary_cat":"none","_seopress_titles_title":"","_seopress_titles_desc":"The IET High Power Resistance Decadence Substitute (HPRS) series is a family of resistance decade banks with a wide choice of high power resistor","_seopress_robots_index":""},"product_brand":[],"product_cat":[249,250,252],"product_tag":[],"class_list":["post-1859","product","type-product","status-publish","has-post-thumbnail","product_cat-calibration-en","product_cat-electrical-calibration","product_cat-decade-banks","first","instock","shipping-taxable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/calibration.consulting\/en\/wp-json\/wp\/v2\/product\/1859","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/calibration.consulting\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/calibration.consulting\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/calibration.consulting\/en\/wp-json\/wp\/v2\/comments?post=1859"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/calibration.consulting\/en\/wp-json\/wp\/v2\/media\/1404"}],"wp:attachment":[{"href":"https:\/\/calibration.consulting\/en\/wp-json\/wp\/v2\/media?parent=1859"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/calibration.consulting\/en\/wp-json\/wp\/v2\/product_brand?post=1859"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/calibration.consulting\/en\/wp-json\/wp\/v2\/product_cat?post=1859"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/calibration.consulting\/en\/wp-json\/wp\/v2\/product_tag?post=1859"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}